Energy source: gas / liquid fuel; Installation: floor; Type: single-circuit (heating only); Heating area (m²): 675; Heat output (kW): 90; Coolant min. T (°C): 60; Coolant max. T (°C): 90; Efficiency (%): 91.84; Combustion chamber: closed (turbocharged); Firebox size: Dimensions (mm): 1030x750x1195
add to listmy lists
Protherm Bizon 90 NO 90 kW
Energy source:gas / liquid fuel
Mount:floor, single-circuit
Boiler power:90 kW, area ~ 675 m²
Combustion chamber:closed, flue 130/200 mm
All specifications
Specifications Bizon 90 NO
Main
Energy sourcegas / liquid fuel
Installationfloor
Typesingle-circuit (heating only)
Heating area675 m²
Technical specs
Heat output90 kW
Power supply230 В
Coolant min. T60 °С
Coolant max. T90 °С
Heating circuit max. pressure5 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency91.84 %
Combustion chamberclosed (turbocharged)
Flue diameter130/200 mm
Safety
Safety systemswater overheating
More specs
Dimensions (HxWxD)1030x750x1195 mm
Weight258 kg
Added to E-CatalogDecember 2012
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Protherm 2026 - new arrivals, bestsellers, and the most relevant models Protherm.
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
We hope the boiler will serve for a long time
29 January 2019 
We use the Bison NO 90 boiler in a warehouse outside the city. Before purchasing, we, together with our partners, studied a lot of technical information about different models, and now we're sharing our experience. The advantage of Bison is its relative economy and energy efficiency, achieved through the special construction of its heat exchanger. Maximum useful heat is extracted from the used warm gases, which many other boilers lack, merely "heating" the outside air at your expense. The two-sided weld seam is done automatically, eliminating the human error of a clumsy welder in principle. The boiler is quite convenient for maintenance and prevention, offering good access. We use mains gas, but in case of force majeure, LNG can be used, and with minor modifications, even diesel. In general, it's exactly what is needed for business. It has a good safety margin— with proper service, the Bison NO should work stably for years without surprises.
relative cost-effectiveness
the price is concerning
use Protherm Bizon 90 NO few months
Add Review