United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Air Conditioners   /   Mitsubishi Heavy

Mitsubishi Heavy SRK63HE/SRC63HE 60 m²

Photos - Air Conditioner Mitsubishi Heavy SRK63HE/SRC63HE 60 m²
Outdated Product
$977.00
Type: split system; Room area (m²): 60; Modes and programs: Operating modes: cooling, heating, dehumidification, ventilation; automode; night mode; Functions: inverter; timer; auto restart; self-diagnosis; Power consumption (cooling/heating): 2170/1830; Cooling capacity (W): 6100; Heating capacity (W): 6300
add to listmy lists
Mitsubishi Heavy SRK63HE/SRC63HE 60 m²
Type:split, wall
Recommended area:60 m²
Consumption:2170/1830 W
Functions:night mode
All specifications
Specifications SRK63HE/SRC63HE
Colour
Typesplit system
Installationwall
Recommended room area60 m²
In boxindoor unit
outdoor unit
Features
Modes and programscooling, heating, dehumidification, ventilation
automode
night mode
Functionsinverter compressor
timer / 24 hours /
auto restart
self-diagnosis
Filtersantibacterial
anti-allergic
deodorizing (charcoal) / photocatalytic /
Performance
Power consumption (cooling/heating)2170/1830 W
Cooling capacity6100 W
Heating capacity6300 W
Noise level (max/min)44/37 dB / outdoor unit — 65 dB /
Refrigerant typeR22
General specs
Display+
Indoor unit dimensions (WxHxD)1098х318х248 mm / weight — 15 kg /
Dimensions of window/outdoor unit (WxHxD)850х640х290 mm / weight — 48 kg /
Added to E-CatalogApril 2009
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Mitsubishi Heavy 2025 - new arrivals, bestsellers, and the most relevant models Mitsubishi Heavy.
Additional features air conditioner Mitsubishi Heavy SRK63HE/SRC63HE:
  • 3 heating modes
  • Boost Mode
  • Automatic blinds
  • Blinds memory
Good to know:

Three heating functions
"Hot Start" (Hot start) delays the flow of cold air into the room when the air conditioner is turned on. "Hot Spurt" ("Hot jet") provides accelerated access to the set temperature during heating operation. The "Hot Keep" function prevents cold air from entering the room during defrosting.

Boost Mode
The air conditioner runs at maximum capacity for 15 minutes. This mode is convenient when you need to quickly reach the desired temperature.

air spiral
The oscillatory movements of the blinds lead to a coma, that the air flow "spins", due to which it reaches the farthest corners of the room.

Self-diagnosis function
In the event of an air conditioner failure, the microcomputer automatically starts the self-diagnosis function, after which a malfunction code is displayed on the display.
Filters