Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers   /   Attack

Attack 45 P 45 kW
without electricity

Photos - Boiler Attack 45 P 45 kW without electricity
Outdated Product
Energy source: gas; Installation: floor; Type: single-circuit (heating only); Heating area (m²): 338; Heat output (kW): 45; Coolant min. T (°C): 35; Coolant max. T (°C): 85; Efficiency (%): 92; Combustion chamber: open (atmospheric); Firebox size: Dimensions (mm): 845x630x525; Weight (kg): 180
add to listmy lists
Attack 45 P 45 kW
without electricity
Energy source:gas
Mount:floor, single-circuit
Boiler power:45 kW, area ~ 338 m²
Combustion chamber:open, flue 165 mm
All specifications
Specifications 45 P
Main
Energy sourcegas
Installationfloor
Typesingle-circuit (heating only)
Heating area338 m²
Technical specs
Heat output45 kW
Power supplyautonomous (no electricity)
Coolant min. T35 °С
Coolant max. T85 °С
Heating circuit max. pressure4 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency92 %
Combustion chamberopen (atmospheric)
Flue diameter165 mm
Inlet gas pressure13 mbar
Max. gas consumption4.7 m³/h
Connections
Gas supply1/2"
Central heating flow1"
Central heating return1"
Safety
Safety systemsgas pressure drop
water overheating
flame loss
draft control
More specs
Dimensions (HxWxD)845x630x525 mm
Weight180 kg
Added to E-CatalogSeptember 2012
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Attack 2025 - new arrivals, bestsellers, and the most relevant models Attack.
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
ATTACK DP is a problematic boiler.
23 September 2013 
ATTACK DP is a problematic boiler. The main problems began in the middle of the third winter, when the boiler began to leak at the bottom and there was a constant drop in pressure in the system. Although the boiler had a 2-year warranty, I turned to the Lithuanian representatives of the manufacturer to join in these problems, since I did not buy a cheap Chinese product, which usually lasts as long as the warranty is given on it. I called repeatedly, but my request was ignored. The boiler was leaking more and more and I decided to disassemble and solve the problem myself. I did this with great fear about poor access to the gap. Luckily the access was very good. From the attached photo it is clear that this is not a welding defect but a design error. Don't criticize the quality of my welding, but I think that with adjustments and additional welding of the two components, the error was corrected. Thank you for reading. Good luck in choosing a boiler.
ATTACK DP is a problematic boiler. Major issues started in the middle of the third winter, when the boiler began leaking at the bottom and there was a constant drop in system pressure. Although the boiler had a 2-year warranty, I contacted the Lithuanian representatives of the manufacturer to address these issues, as I did not buy a cheap Chinese product that usually lasts only as long as its warranty. I called repeatedly, but my complaint was ignored. The boiler leaked more, and I decided to take it apart and solve the problem myself. I did this with great concern about the difficult access to the break. Fortunately, access was very good. From the attached photo, it is clear this is not a welding defect but a design flaw. Do not criticize the quality of my welding, but I believe that by adjusting and additionally welding the two components, the error was corrected. Thank you for reading. Good luck choosing a boiler.
The ATTACK DP is a problematic boiler. The main issues began in the middle of the third winter when the boiler started leaking from the bottom and experiencing constant pressure drops in the system. Although there was a 2-year warranty on the boiler, I reached out to the Lithuanian representatives of the manufacturer to address these issues because I did not buy a cheap Chinese product, which usually lasts only as long as the warranty is given. I called repeatedly, but my request was ignored. The boiler continued to leak more and more, so I decided to disassemble it myself and fix the problem. I did this with great fear due to the potential for poor access to the rupture. Fortunately, the access was very good. From the attached photo, you can see that this is not a welding defect but a design flaw. Please don't criticize the quality of my welding, but I believe that by adjusting and additionally welding the two components, the error has been corrected. Thank you for reading. Good luck in choosing a boiler.
Igoruse Attack 35 P more than year
Add Review