APC AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U
APC Metered Rack PDUs offer resilient power distribution and actively measure display and log volts amps real power (kW) & en... moreergy (kWh). This PDU offers LCD display real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed configured and managed remotely via EcoStruxure IT Web SNMP and Command Line Interface. Power is supplied to the PDU at 220-240 volts via IEC 309 2P + E plug with a 3m (10 ft) cord while power comes out at 230 volts through (18) C13 and (2) C19 locking outlets. It integrates with EcoStruxure IT and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product this unit comes with a verified product environment profile including carbon footprint scope 3 emissions and end of life instructions.
APC Metered Rack PDU ZeroU 2G - Power Distribution Strip AP8858EU3
. APC Switched Rack Power Distribution Units (PDUs) enable advanced user-customizable power control and active monitoring. Re... moremote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring a temperature/humidity sensor port locking IEC receptacles and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access configure and control Switched Rack PDUs through secure Web SNMP or Telnet Interfaces. Network ManagementFull-featured network management interfaces that provide standards-based management via Web SNMP and Telnet. Allows users to access configure and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Remote individual outlet controlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Power delaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Integrates with InfraStruXure CentralAn IT-ready scalable monitoring system that collects organizes and distributes critical alerts surveillance video and key information providing a unified view of complex physical infrastructure environments from anywhere on the network. Single input power sourceSupply power from one branch whip to multiple pieces of equipment conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. What's in the box? . Installation guideLocking input power cordRack mounting bracketsSafety guideSerial configuration cable. .
APC Metered Rack PDU ZeroU 2G - Power Distribution Strip AP8858EU3
. APC Switched Rack Power Distribution Units (PDUs) enable advanced user-customizable power control and active monitoring. Re... moremote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring a temperature/humidity sensor port locking IEC receptacles and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access configure and control Switched Rack PDUs through secure Web SNMP or Telnet Interfaces. Network ManagementFull-featured network management interfaces that provide standards-based management via Web SNMP and Telnet. Allows users to access configure and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Remote individual outlet controlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Power delaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Integrates with InfraStruXure CentralAn IT-ready scalable monitoring system that collects organizes and distributes critical alerts surveillance video and key information providing a unified view of complex physical infrastructure environments from anywhere on the network. Single input power sourceSupply power from one branch whip to multiple pieces of equipment conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. What's in the box? . Installation guideLocking input power cordRack mounting bracketsSafety guideSerial configuration cable. .
EU PLUG.APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit pr... moreotection.User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads.Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership.Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers.Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.Specifications:- Design.- PDU types:Metered.- Rack capacity:0U.- MountingVertical.- Ports & interfaces.- AC outlets quantity:20 AC outlet(s).- Power plugIEC309.- AC outlet types:C13 coupler, C19 coupler.- Input connection typeIEC 309 16A 2P+E.- Output connections18x IEC 320 C13 2x IEC 320 C19.- Features.- Cable length3 m.- CertificationCSA C22.2 No.60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH.- Management Features.- MonitoringCurrent, Power, Voltage.- Power.- AC input frequency50.- 60 Hz.- Nominal output voltage230 V.- Power.- Load capacity3680 VA.- Maximum input current per phase16 A.- Maximum total current draw per phase16 A.- Maximum power3680 W.- Weight & dimensions.- Dimensions (WxDxH)56 x 44 x 902 mm.- Weight2.93 kg.- Packaging data.- Package dimensions (WxDxH)162 x 107 x 1124 mm.- Package weight4.92 kg.- Operational conditions.- Operating temperature (T-T)5.- 45 °C.- Storage temperature (T-T)-25.- 65 °C.- Operating relative humidity (H-H)5.- 95%.- Storage relative humidity (H-H)5.- 95%.