Comparison Cooper&Hunter Unitherm 4 Split CH-HP16SIRM4 15 kW vs Electrolux EMHP-16Y/N8+EHB-160/N8 16 kW

Add to comparison
Cooper&Hunter Unitherm 4 Split CH-HP16SIRM4 15 kW
Electrolux EMHP-16Y/N8+EHB-160/N8 16 kW
Cooper&Hunter Unitherm 4 Split CH-HP16SIRM4 15 kWElectrolux EMHP-16Y/N8+EHB-160/N8 16 kW
Outdated ProductOutdated Product
TOP sellers
Two stage rotary compressor. When the heating element is activated, the temperature of the heat carrier can warm up to 80 °C.
Heat sourceair-waterair-water
Suitable forheating and DHWheating and DHW
In box
In box
indoor unit (hydromodule)
outdoor unit
indoor unit (hydromodule)
outdoor unit
Specs
Operating modeheating and coolingheating and cooling
Max. heat output15.5 kW16 kW
Max. cooling output13 kW14.2 kW
Power consumption (heating)3.44 kW3.56 kW
Power consumption (cooling)3.6 kW3.94 kW
EER3.61
Power source400 V400 V
Electric heater9 kW
Minimum operating temperature-25 °C-25 °C
Max. water temperature60 °C65 °C
Compressor
inverter
inverter
Energy efficiency
t°C outside77
Supply t°C35 °C35 °C
COP4.54.5
SCOP (W35)4.62
Energy efficiency class (W35)A+++
SCOP (W55)3.41
Energy efficiency class (W55)A++
t°C outside7-7
Supply t°C45 °C55 °C
COP3.622.02
More specs
Control via smartphone++
RefrigerantR32R32
Noise level29 dB
Outdoor unit noise level55 dB
Country of brand originUSASweden
Dimensions860x460x318 mm790x420x270 mm
Outdoor unit dimensions940x820x460 mm865x1118x523 mm
Hydromodule weight62 kg37 kg
Outdoor unit weight58 kg112 kg
Added to E-Catalogjuly 2024june 2024
Glossary

Max. heat output

The maximum heat output generated by a heat pump is the amount of heat it can transfer from the outdoors into the heating system and/or domestic hot water.

The heat output is the most important spec of a heat pump. It directly determines its efficiency and ability to provide the required amount of heat. Note that this spec is shown for optimal operating conditions. Such conditions are rare, so the actual output heat is usually noticeably lower than the maximum; this must be taken into account when choosing. There are special formulas for calculating the optimal value of the maximum heat output, depending on the specific condition.

Max. cooling output

Maximum cooling output delivered by the pump.

The pump operates in the cooling mode removing excess heat from the room to the environment — it plays the role of an air conditioner. The required cooling capacity depends on the area of the building, the specs of its thermal insulation and some other factors; methods of its calculation can be found in special sources. Also note here that conventional heating equipment (radiators, underfloor heating) is not suitable for cooling, for this it is necessary to use special equipment (for example, fan coil units).

Power consumption (heating)

Electric power consumed by the heat pump when operating only for heat transfer, without the use of an additional heating element (if any, see below). The ratio of thermal power to power input determines the thermal coefficient COP (see below) and, accordingly, the overall efficiency of the unit. It also affects overall power consumption (and therefore electricity bills), as well as some power and connection requirements — for example, models powered by 230 V and with a power of more than 5 kW cannot work from an outlet and require a special connection to the mains.

Power consumption (cooling)

For more information on power consumption, see the paragraph above. Here is indicated the consumption of electricity during operation in the cooling.

EER

EER is the ratio of the heat pump's output cooling energy to the input electrical energy.

The higher this parameter, the more economical the device is and the higher its energy efficiency class when cooling. Each class has clear requirements for EER.

Electric heater

The power of the heating element installed in the device (if such a function is available).

It isan electric heater in the form of a tube with an incandescent filament inside. Such a heater plays an auxiliary role; it is used when the heat output of the pump itself is not enough — for example, with a significant drop in temperature outside. The main advantage of heating elements is that their efficiency does not depend on outdoor conditions. And the main disadvantage is the high energy consumption. If the heat pump can transfer much more heat energy than it consumes electricity, then the heat output of the heating element is approximately equal to the consumed one. That is why the specs indicate the power of the heating element in general, without specifying what it is about: the indicated figure corresponds to both the heating power and energy consumption. These parameters are similar to those of the heat pump itself; see above for more details.

Max. water temperature

The highest temperature to which the pump can heat the coolant. It is worth noting that such indicators can be achieved at a fairly high temperature of air or ground. And since heat pumps are used during the cold season, the actual maximum temperature, usually, is less than theoretically achievable. Nevertheless, this parameter makes it possible to evaluate the capabilities of the unit or its suitability for certain tasks.

SCOP (W35)

Like the standard COP (see above), this parameter describes the overall efficiency of the heat pump in heating operation and is calculated by the formula: thermal (useful) power divided by electricity consumption. The higher the coefficient, the more efficient the device. And the difference between COP and SCOP is that COP is measured under strictly standard conditions (outside temperature +7 °C, full workload), and SCOP takes into account seasonal temperature fluctuations (for Europe), changes in pump operating modes, the presence of an inverter and some other options. Thanks to this, SCOP is closer to real indicators, and since 2013 this coefficient has been taken as the main one in the territory of the European Union. However, this characteristic is also used for devices supplied to other countries with a similar climate. And in a specific case, measurements are carried out at a water supply temperature of 35 °C.

Energy efficiency class (W35)

The energy efficiency class characterizes the efficiency of electricity consumption by a heat pump. In this case, the final result is at a water supply temperature of 35°. The most energy efficient models have class A with a certain number of pluses (A+, A++, A+++, the more pluses — the lower the energy consumption), the more energy consuming — A, B, C and so on as energy efficiency decreases.