Device typehybrid inverterhybrid inverter
Network type1 phase (230 V)/3 phase (400 V)1 phase (230 V)/3 phase (400 V)
Maximum efficiency97.6 %97.6 %
Euro efficiency97 %97 %
AC input / output
Rated power12000 VA12000 VA
Rated power12000 W12000 W
Peak power18000 W18000 W
Rated AC current18.2 A17.4 A
Maximum AC power25 А19.2 А
Output waveformpure sinepure sine
Batteries and DC charging
Number of battery inputs1 шт1 шт
Maximum charge current50 А37 А
Solar PV panels
Max. power15.6 kW15.6 kW
Operating voltage PV150 – 850 В150 – 850 В
Short circuit current55 А69 А
Controller2xMMPT2xMMPT
Number of strings22
Features and control
Functions
generator connection
parallel connection
built-in monitoring
parallel connection
built-in monitoring
Control interfaces
RS485
RS485
Protection
reverse polarity protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
General
Displaycolourcolour
Coolingactive (fans)active (fans)
Noise level55 dB
Casing protection classIP65
Operating temperature-40 °C ~ +60 °C-40 °C ~ +60 °C
Dimensions450x540x385 mm638x408x237 mm
Weight45 kg30.5 kg
Added to E-Catalogmarch 2025november 2023
Glossary

Rated AC current

The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).

Maximum AC power

The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.

Maximum charge current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.

Short circuit current

The maximum solar panel short circuit current that the inverter can accept without the risk of breakdown or emergency shutdown. The parameter is usually indicated in amperes.

Functions

UPS function. Inverters with a UPS function automatically switch to battery-powered mode when there is insufficient power generation from solar panels or in cases where the main power source is disconnected. This ensures load redundancy. Note that switching may not occur instantly, but with a certain delay (about 10-30 ms).

Connecting the generator. Inverters that support the generator connection function significantly increase the reliability and efficiency of autonomous solar energy systems. In practice, the function can be implemented in several basic ways. First, the system can automatically turn the generator on and off depending on the battery charge level or current power consumption, ensuring efficient use of resources and minimizing fuel consumption. Secondly, switching the load to the generator can be carried out when there is a shortage of electricity generation from solar panels. And thirdly, the generator can be used to maintain an optimal battery charge level so that the system is in full readiness at any time.

Parallel connection. The inverter has special connectors through which two or more devices can be connected to a single electrical network. Parallel connection is used when one inverter is not able to pull the entire load from solar panels and the input power exceeds the capabilities of the device itself.

Built-in monitoring. The presence of a built-in monitoring module on board the inverter, which collects information about the productivity of solar panels, allows you to monitor energy production and consumption, as well as monitor the performance of the system as a whole. Moreover, these parameters can often be viewed and controlled in real time (including through a mobile application for a smartphone). The monitoring module is usually connected to the Internet via a Wi-Fi network.

Protection

Overload protection. A protection system against connecting an off-design load whose power consumption exceeds the capabilities of the inverter for solar panels. In such situations, the power to the outlets is automatically turned off, since overloading the device promises failure and even fire. Triggering of the protection is usually accompanied by a sound and/or light signal.

Overheat protection. This protection is triggered when the temperature inside the inverter rises critically. When such situations occur, the device turns off, which avoids breakdowns. In the future, some models will automatically turn on when the temperature normalizes, while others must be turned on manually. Note that overheating is caused not only by malfunctions, but also by completely normal reasons - for example, long-term operation at high air temperatures. Typically, overheating protection is accompanied by a sound and/or light signal.

Protection against ↑ or ↓ battery voltage. A protection system that prevents the inverter from being supplied with excessively high or excessively low voltage from the batteries. When the operating voltage range is exceeded, the device automatically turns off to avoid breakdowns and other troubles. A sound and/or light signal can warn of protection activation.

Short circuit protection. Protec...tion that is triggered when the output current increases critically (for example, due to a foreign metal object getting between live parts of the load). To avoid breakdowns and failure, the power at the inverter output is automatically turned off. Triggering of the protection system is usually accompanied by a sound and/or light signal.

Reverse polarity protection. Protection system in case of incorrect polarity of connection. If the “plus” and “minus” do not match, the inverter is disconnected from the power supply in order to avoid damage to the electronic components. Notification of protection activation is often provided by a sound and/or light signal.

— Protection class. The class of protection against dust and moisture provided by the inverter housing for solar panels. Indicated according to the IP standard by two numbers: the first (from 1 to 6) means resistance to penetration of foreign objects and dust, the second (from 1 to 8) - protection from moisture. The higher the number, the higher the level of protection provided. Also note that instead of the first digit in the designation of the protection class, “X” may be indicated - for example, IPX7. In this case, the device is not certified for dust protection, although in fact the level of such protection may be quite high. So, in the example with moisture resistance “7”, the case can be completely immersed in water - which means it is closed very tightly from dust.

The IP protection level is especially important to consider when choosing models for outdoor use and installation in rooms with high humidity levels - they are the ones most susceptible to adverse environmental influences. A high IP class will guarantee stable operation of the inverter for solar panels in such difficult conditions.

Noise level

The noise level in decibels (dB) produced by the inverter during operation. The lower this indicator, the more comfortable the use of the equipment will be, which is especially important for residential premises.

Note that decibels are a non-linear quantity, so the easiest way to assess the noise level is to use comparative tables. Here is a simplified table for the range that most modern inverters fall into:

35 dB – conversation in muted tones;
40 dB – quiet conversation; maximum noise level allowed in residential premises during the daytime;
45 – 50 dB – conversation in a normal tone;
55 dB - background noise in an office without special noise sources;
60 dB - loud conversation;
65 dB - city street with average traffic intensity;
70 dB - a conversation between several people in a raised voice.

Casing protection class

The protection class of the housing is traditionally indicated according to the IP standard - the “IP” marking with two numbers. The first describes protection against the penetration of dust and foreign objects. The following options may occur:

— 2. Protection against objects with a thickness of 12.5 mm or more, prevents the penetration of fingers.
— 3. Protection against objects with a thickness of 2.5 mm, in particular many tools.
— 4. Protection from objects with a thickness of 1 mm (most wires).
— 5. Complete protection from contact of the “internals” with foreign objects, resistance to dust (it can penetrate inside the case, but in scanty quantities that do not affect the operation of the device).
— 6. Completely closed housing, preventing dust from getting inside.

The second digit in the IP marking characterizes the degree of protection against moisture:

— 0. Complete absence of any protection; water ingress into the housing is not allowed.
— 1. Protection from vertical drops of water.
— 2. Protection against vertical drops when the body is tilted up to 15° from the standard position.
— 3. Protection against splashes falling on the body at an angle of up to 60° to the horizontal, the minimum indicator that allows us to talk about resistance to rain.
- 4. Protection against splashes from any direction, allows you to safely withstand rain and strong winds.
— 5. Protection from water jets from any...direction, resistance to storms.
— 6. Protection from strong water jets or strong sea waves (when the device can be completely hidden under the wave for a short time).
— 7. Possibility of short-term immersion to a depth of up to 1 m (without the possibility of constant operation in submerged mode).
— 8. possibility of long-term immersion to a depth of more than 1 m (with the possibility of constant operation in submerged mode).

The degree of IP protection is especially important to consider when choosing outdoor models - they are the ones most susceptible to adverse environmental influences. This parameter is also important when placing the inverter in rooms with high humidity levels.
Deye SUN-12K-SG01HP3-EU-AM2 often compared