United Kingdom
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters & Controllers

Comparison Anern EVO Series SCI-EVO-4200 vs Anern EVO Series SCI-EVO-6200

Add to comparison
Anern EVO Series SCI-EVO-4200
Anern EVO Series SCI-EVO-6200
Anern EVO Series SCI-EVO-4200Anern EVO Series SCI-EVO-6200
Expecting restockOutdated Product
TOP sellers
Device typehybrid inverterhybrid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency98 %98 %
AC input / output
Rated power4200 VA6200 VA
Rated power4200 W6200 W
Peak power7200 W12400 W
Rated AC current18.2 A
Maximum AC power27 А
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage24 В48 В
Number of battery inputs1 шт1 шт
Maximum charge current120 А120 А
Solar PV panels
Max. power6.2 kW6.5 kW
Operating voltage PV60 – 450 В90 – 450 В
Controller1xMMPT1xMMPT
Number of strings1
Features and control
Functions
UPS function
built-in monitoring
built-in monitoring
Control interfaces
LAN (RJ45)
Wi-Fi
LAN (RJ45)
Protection
reverse polarity protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
General
Displaymonochromecolour
Coolingactive (fans)active (fans)
Casing protection classIP20
Operating temperature-10 °C ~ +50 °C-10 °C ~ +50 °C
Dimensions420x350x110 mm450x350x110 mm
Weight9 kg10 kg
Added to E-Catalognovember 2024november 2023
Glossary

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Rated AC current

The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).

Maximum AC power

The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.

Connection voltage

The efficiency of the solar system, laid down by the manufacturer of the inverter, directly depends on this parameter. The following battery voltage options are most widely used: 12 V, 24 V and 48 V.

Max. power

The maximum allowable input power from solar panels, expressed in kilowatts (kW). Let us remember that 1 kW contains 1000 W.

When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.

Number of strings

Strings in solar energy are chains of panels connected in series. With this connection method, the voltage of the solar panels is summed up, and the current remains constant, which allows you to significantly increase the power generation capacity while maintaining a fairly low current and without the need to use large-section wires.

Specifically, this paragraph indicates the maximum number of strings that can be connected to the inverter for solar panels.
Anern EVO Series SCI-EVO-4200 often compared