Comparison Must PV18-1512 VPM vs Volt Polska Sinus PRO Ultra 2000 12/230V

Add to comparison
Must PV18-1512 VPM
Volt Polska Sinus PRO Ultra 2000 12/230V
Must PV18-1512 VPMVolt Polska Sinus PRO Ultra 2000 12/230V
Outdated ProductOutdated Product
User reviews
0
1
0
0
TOP sellers
Device typeoff-grid inverteroff-grid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency98 %93 %
AC input / output
Rated power1500 VA1000 VA
Rated power1500 W1000 W
Peak power3000 W2000 W
Rated AC current6.5 A
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage12 В12 В
Number of battery inputs1 шт1 шт
Maximum charge current70 А70 А
Solar PV panels
Max. power0.72 kW
Operating voltage PV15 – 130 В15 – 105 В
Controller1xMMPT
Number of strings1
Features and control
Functions
UPS function
generator connection
UPS function
generator connection
built-in monitoring
Control interfaces
USB
RS485
USB
LAN (RJ45)
Protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
General
Displaymonochromecolour
Coolingactive (fans)active (fans)
Casing protection classIP21
Operating temperature0 °C ~ +50 °C0 °C ~ +50 °C
Dimensions318x255x110 mm337x224x97 mm
Weight5.5 kg5 kg
Added to E-Catalogjuly 2024november 2023
Glossary

Maximum efficiency

Inverter efficiency for solar panels.

The efficiency indicator is the percentage ratio between the amount of energy that the device delivers to the load and the energy consumed from the solar panel. The higher this parameter, the more efficient the operation of the device and the lower the losses during conversion. In modern inverters for solar panels, efficiency values of up to 90% are considered average, and above 90% are considered good.

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Rated AC current

The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).

Max. power

The maximum allowable input power from solar panels, expressed in kilowatts (kW). Let us remember that 1 kW contains 1000 W.

When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.

Controller

Built-in Maximum Power Point Tracking (MPPT) system for monitoring the maximum power points of photovoltaic modules in solar panels. It determines the most optimal ratio of voltage and current drawn from the solar panels, thereby ensuring maximum performance of individual strings (chains of series-connected panels). An MPPT controller is useful under any external weather changes, allowing solar panels to generate power even in cloudy conditions. Modern inverter models can contain either one or several MPPT trackers (up to six), which allow for the connection of multiple arrays with different orientations and angles of inclination, thereby eliminating the mutual influence of one array on another. Each MPPT controller output is designed to connect one string.

Number of strings

Strings in solar energy are chains of panels connected in series. With this connection method, the voltage of the solar panels is summed up, and the current remains constant, which allows you to significantly increase the power generation capacity while maintaining a fairly low current and without the need to use large-section wires.

Specifically, this paragraph indicates the maximum number of strings that can be connected to the inverter for solar panels.
Must PV18-1512 VPM often compared
Volt Polska Sinus PRO Ultra 2000 12/230V often compared