Device type
—
Autonomous inverter. Voltage and power converters that are not connected to an external electrical network. They are supposed to be used as part of autonomous photovoltaic systems - such inverters generate electricity, which is spent exclusively for the needs of the household. It can be consumed directly by household appliances or accumulated in batteries. This type of inverter is often called off grid.
—
Network inverter. Inverters operating synchronously with the external power supply network. They are designed to convert solar energy into alternating power with the parameters of the general network. Grid-connected inverters are used in battery-free systems - all generated energy is used for own consumption, and the excess is transferred to the network at a “feed-in tariff”. To do this, some indicators of generated electricity are adjusted, in particular, amplitude differences are eliminated, the network frequency is equalized, etc. Grid-tied inverters are also known as on-grid inverters.
—
Hybrid inverter. Battery-grid inverters are peculiar hybrids of autonomous and network converters. Actually, this is where the name hybrid comes from. Inverters of this type work with battery chains, and excess electricity is sent to the general network. This ensures the energy independence of the system based on solar panels with the ability to use the energy a
...ccumulated in the batteries without disconnecting from the network. For example, if DC power is prioritized, power is primarily supplied from batteries, and any energy shortages are supplied from the external grid. This comes in handy in case of bad weather conditions or insufficient power generated by solar panels. If electricity is generated in excess, the excess energy is released into the general network at a “feed-in tariff”.
— Inverter for campers (motorhomes). Such narrow-niche inverters usually work in conjunction with a branded charging station - while staying at a campsite, it charges the vehicle’s battery. And while driving, such inverters are connected to the car’s alternating power generator and with their help, the energy reserves in the battery cells of the charging station are replenished.Maximum efficiency
Inverter efficiency for solar panels.
The efficiency indicator is the percentage ratio between the amount of energy that the device delivers to the load and the energy consumed from the solar panel. The higher this parameter, the more efficient the operation of the device and the lower the losses during conversion. In modern inverters for solar panels, efficiency values of up to 90% are considered average, and above 90% are considered good.
Peak power
The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.
Maximum charge current
The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.
Total battery capacity
The total capacity of the batteries connected to the inverter, expressed in ampere-hours (Ah). The larger the capacity, the longer the battery life will be, all other things being equal. For example, a 100Ah battery can theoretically deliver 100A for one hour, or 10A for 10 hours.
Separately, we note that batteries with the same rated voltage can be compared by capacity in ampere-hours - this is due to the characteristics of the ampere-hour as a unit of capacity. If you need to compare batteries of different capacities, you need to use data in watt hours (see below). And using special formulas you can calculate the capacity in Wh based on the capacity in Ah and the rated voltage of the battery.
Total battery capacity
The total capacity of the connected batteries in watt-hours (Wh). In fact, this is the amount of energy that is supposed to be stored in the battery. The larger the capacity, the longer the battery life of the connected equipment will be, all other things being equal. On the other hand, this parameter also affects the dimensions, weight and price of the battery. Based on the capacity in watt-hours, batteries can be compared with each other.
Max. power
The maximum allowable input power from solar panels, expressed in kilowatts (kW). Let us remember that 1 kW contains 1000 W.
When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.
Operating voltage PV
The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.
Controller
Built-in Maximum Power Point Tracking (MPPT) system for monitoring the maximum power points of photovoltaic modules in solar panels. It determines the most optimal ratio of voltage and current drawn from the solar panels, thereby ensuring maximum performance of individual strings (chains of series-connected panels). An
MPPT controller is useful under any external weather changes, allowing solar panels to generate power even in cloudy conditions. Modern inverter models can contain either one or
several MPPT trackers (up to six), which allow for the connection of multiple arrays with different orientations and angles of inclination, thereby eliminating the mutual influence of one array on another. Each MPPT controller output is designed to connect one string.