United Kingdom
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters & Controllers

Comparison LuxPower LXP-6K Hybrid-MG vs LuxPower LXP-5K Hybrid

Add to comparison
LuxPower LXP-6K Hybrid-MG
LuxPower LXP-5K Hybrid
LuxPower LXP-6K Hybrid-MGLuxPower LXP-5K Hybrid
Outdated ProductOutdated Product
TOP sellers
The Hybrid-MG series has the ability to connect up to 10 devices in parallel, the Hybrid series does not have parallel connection.
The Hybrid-MG series has the ability to connect up to 10 devices in parallel, the Hybrid series does not have parallel connection.
Device typehybrid inverterhybrid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency97.9 %97.9 %
Euro efficiency97 %97 %
AC input / output
Rated power6000 VA5000 VA
Rated power6000 W5000 W
Rated AC current26 A21.7 A
Maximum AC power26 А25 А
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage48 В48 В
Number of battery inputs1 шт1 шт
Maximum charge current80 А80 А
Solar PV panels
Max. power8 kW8 kW
Operating voltage PV120 – 500 В120 – 500 В
Short circuit current40 А40 А
Controller2xMMPT2xMMPT
Features and control
Functions
UPS function
generator connection
parallel connection
built-in monitoring
UPS function
generator connection
built-in monitoring
Control interfaces
Wi-Fi
LAN (RJ45)
RS485
Wi-Fi
LAN (RJ45)
RS485
Protection
reverse polarity protection
short circuit protection
overload protection
reverse polarity protection
short circuit protection
overload protection
General
Displaymonochromemonochrome
Coolingpassivepassive
Noise level25 dB25 dB
Casing protection classIP65IP65
Operating temperature-25 °C ~ +60 °C-25 °C ~ +60 °C
Dimensions551x451x184 mm551x451x184 mm
Weight20 kg20 kg
Added to E-Catalognovember 2023november 2023
Glossary

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Rated AC current

The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).

Maximum AC power

The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.

Functions

UPS function. Inverters with a UPS function automatically switch to battery-powered mode when there is insufficient power generation from solar panels or in cases where the main power source is disconnected. This ensures load redundancy. Note that switching may not occur instantly, but with a certain delay (about 10-30 ms).

Connecting the generator. Inverters that support the generator connection function significantly increase the reliability and efficiency of autonomous solar energy systems. In practice, the function can be implemented in several basic ways. First, the system can automatically turn the generator on and off depending on the battery charge level or current power consumption, ensuring efficient use of resources and minimizing fuel consumption. Secondly, switching the load to the generator can be carried out when there is a shortage of electricity generation from solar panels. And thirdly, the generator can be used to maintain an optimal battery charge level so that the system is in full readiness at any time.

Parallel connection. The inverter has special connectors through which two or more devices can be connected to a single electrical network. Parallel connection is used when one inverter is not able to pull the entire load from solar panels and the input power exceeds the capabilities of the device itself.

Built-in monitoring. The presence of a built-in monitoring module on board the inverter, which collects information about the productivity of solar panels, allows you to monitor energy production and consumption, as well as monitor the performance of the system as a whole. Moreover, these parameters can often be viewed and controlled in real time (including through a mobile application for a smartphone). The monitoring module is usually connected to the Internet via a Wi-Fi network.
LuxPower LXP-6K Hybrid-MG often compared