Network type
—
Single-phase (230 V). Single-phase power is well known from classic 230 V household sockets. However, this also often includes models for other alternating voltage values - for example, 110 V.
—
Three-phase (400 V). Three-phase power supply with a voltage of 400 V is used mainly for energy-hungry devices for which 230 V networks do not provide enough power. This option can be used both for private households and in the industrial sector.
— Single-phase / three-phase. Models with the ability to connect to both single-phase power supply at 230 V and three-phase power supply at 400 V. This allows them to be used with both household and industrial networks - depending on which option is more convenient at the moment.
—
DC (constant voltage). This category usually includes a few inverters for campers (motorhomes) (see “Device Type”). They are designed for operation in automotive networks with a constant voltage of 12/24 V.
Euro efficiency
The European inverter efficiency is measured based on several load values (e.g. 10%, 30%, 50%, 100%), which better reflects the actual operating conditions of the device. Indeed, in fact, inverters rarely operate at full power in constant mode. To calculate the Euro index, the weighted average of the inverter efficiency at different load levels is taken into account. Note that there is no single generally accepted formula here - it may vary depending on the specific standard or equipment manufacturer. Nevertheless, Euro efficiency allows you to more accurately assess the efficiency of the inverter under conditions of partial and full power use
Peak power
The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.
Rated AC current
The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).
Maximum AC power
The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.
Connection voltage
The efficiency of the solar system, laid down by the manufacturer of the inverter, directly depends on this parameter. The following battery voltage options are most widely used:
12 V,
24 V and
48 V.Maximum charge current
The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.
Operating voltage PV
The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.
Short circuit current
The maximum solar panel short circuit current that the inverter can accept without the risk of breakdown or emergency shutdown. The parameter is usually indicated in amperes.