United Kingdom
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters & Controllers

Comparison Axioma ISMPPT BF 1200 vs Axioma ISPWM 2000

Add to comparison
Axioma ISMPPT BF 1200
Axioma ISPWM 2000
Axioma ISMPPT BF 1200Axioma ISPWM 2000
Outdated ProductOutdated Product
TOP sellers
PWM controller
Device typehybrid inverterhybrid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency93 %93 %
AC input / output
Rated power1200 VA2000 VA
Rated power1200 W1600 W
Peak power2400 W3200 W
Maximum AC power70 А
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage12 В24 В
Number of battery inputs1 шт
Maximum charge current80 А70 А
Solar PV panels
Max. power2 kW
Operating voltage PV60 – 300 В90 – 280 В
Controller1xMMPT1xMMPT
Number of strings11
Features and control
Functions
UPS function
UPS function
Control interfaces
RS232
USB
Protection
 
short circuit protection
overload protection
General
Displaymonochromemonochrome
Coolingpassiveactive (fans)
Operating temperature-10 °C ~ +50 °C-10 °C ~ +50 °C
Dimensions90х288х357 mm88x225x320 mm
Weight6.5 kg5.5 kg
Added to E-Catalogseptember 2023may 2023
Glossary

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Maximum AC power

The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.

Connection voltage

The efficiency of the solar system, laid down by the manufacturer of the inverter, directly depends on this parameter. The following battery voltage options are most widely used: 12 V, 24 V and 48 V.

Number of battery inputs

Number of points for connecting batteries to the inverter. Household models usually have one such input, while powerful and productive models may have two or even three battery inputs. Multiple inputs allow the system to be scaled by adding batteries without having to replace the inverter.

Maximum charge current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.

Max. power

The maximum allowable input power from solar panels, expressed in kilowatts (kW). Let us remember that 1 kW contains 1000 W.

When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.
Axioma ISMPPT BF 1200 often compared