Performance (Δt ~50 °C)
Water heater performance when heating water by approximately 50 °C above the initial temperature.
Productivity is the maximum amount of hot water the unit can produce in a minute. It depends not only on the power of the heater as such, but also on how much water needs to be heated: the higher the temperature difference ΔT between cold and heated water, the more energy is required for heating and the smaller the volume of water with which the unit can handle in this mode. Therefore, the performance of water heaters must be indicated for specific options ΔT — namely 25 °C, 40 °C and/or 50 °C. And it is worth choosing according to this indicator taking into account the real needs for hot water: exactly how much and what temperature is needed for a particular situation. Methods of such calculations can be found in special sources.
Recall that water begins to be felt by a person as warm somewhere from 40 °C, as hot — somewhere from 50 °C, and the temperature of hot water in central water supply systems (according to official standards) is at least 60 °C. Thus, Δt~50 °C can be described as a very significant degree of heating: it allows even water with a temperature of about zero to be heated to the “hot” state, and the level of 60 °C can be reached at an initial temperature of only 10 °C (this temperature, for example, it is quite possible to meet in cold tap water even in the off-season, not to mention the summer). However, in modern water heaters, operati...ng temperatures above 60 °C are often found; to achieve them, you usually have to work with ΔT greater than 50 °C — respectively, and the actual performance is less than indicated in this paragraph. Nevertheless, it is this parameter that is closest to the real capabilities of the water heater when it comes to the full conversion of cold water into hot.
Efficiency
Heater efficiency.
Recall that efficiency is the ratio (in percent) between useful work and total energy consumed. In water heaters, this parameter is indicated mainly for gas models of an instant heat design. It describes what part of the heat from the gas burning in the combustion chamber is transferred to the water; accordingly, the higher the efficiency — the more efficient this model, the less gas it will need to heat a certain volume of water to a certain temperature. However, the increase in efficiency inevitably affects the price of the device; on the other hand, additional spending can quickly pay off due to gas savings.
In general, modern instant gas heaters have fairly high efficiency — from 81 – 84% in the most modest models to 90% or more in the most efficient ones.
Flue diameter
Flue diameter for which the gas water heater is designed (see "Energy source").
This parameter is useful primarily for the selection and installation of a flue for a specific device. At the same time, it is worth remembering that the design of the duct differs depending on the type of combustion chamber (see above). So, for an open chamber, an ordinary pipe is used; in such cases, one diameter is indicated in the characteristics. But closed (turbocharged) combustion chambers are usually made under the so-called coaxial flue — a channel of the "pipe in pipe" type, where combustion products are brought out through the inner pipe, and the air necessary for fuel combustion is taken from the outside through the outer pipe. For such chimneys, two diameters are indicated for each of the pipes.
Safety systems
The safety of water heaters can be carried out by such functions as
overheat protection frost protection,
dry heating protection,
surge protection,
electrical protection (RCD),
anti-legionella,
gas control and
draft sensor. More about them:
— Overheat protection. Water heater safety system that automatically turns off the power supply or gas supply (depending on the type) when the heating element reaches a critical temperature. It avoids overheating and the troubles associated with it, ranging from heater failure to fire.
— Frost protection. Function to prevent freezing of water in the circuits, tank and/or heat exchanger of the water heater. It will be useful when the device is installed in a room with a low temperature and works with long breaks. Frozen water expands, which can damage the device; to avoid this, the frost protection monitors the temperature of the water in the device and turns on the heating when this temperature drops to a critical level.
— Dry heating protection. A safety system that prevents the heater from being switched on without the presence of water in it. Since the heating element does not transfer heat to the water when turned on, it heats up very q
...uickly and, in a short time, reaches a high temperature that can lead to damage to the heater and even to a fire. The presence of protection against switching on without water allows you to avoid such unpleasant consequences.
— Voltage surge protection. System for protecting the heater from power surges. Electronically controlled models are usually equipped with such protection (see Control) since it is the control electronics that are most sensitive to problems with the power supply. Note that the capabilities of such systems are noticeably more modest than those of specialized stabilizers or protective systems: the “hardware” of a water heater can smooth out relatively weak power surges, but in case of serious failures, it will most likely simply turn off the device to avoid damage. However, this feature will be useful; except that in very unstable electrical grids, prone to frequent fluctuations, such a heater may require an external stabilizer.
— Electrical protection (RCD). Built directly into the heater, the RCD is a residual current device. Such a device is primarily intended to protect people from electric shock — for example, if the insulation is damaged and electricity leaks into the case or water. When a person comes into contact with this electricity, a so-called leakage current occurs. The RCD reacts to it and almost instantly turns off the power to the boiler, preventing electric shock.
Note that such safety devices are standardly installed directly in switchboards. However, the presence of an RCD in the water heater provides additional security. Naturally, such equipment is found mainly in electric models.
— Safety valve. A safety system that prevents a critical increase in water pressure in the heater. Usually, this protection is based on a safety valve that opens when a certain pressure level is reached and drains excess water, avoiding damage to the heater.
— Gas control. Gas heater safety system that automatically shuts off the gas supply in the event of a burner flame failure. It avoids filling the room with gas and possible unpleasant, and even tragic consequences. Resuming the gas supply after the protection is triggered must be done manually.
— Draft sensor. A sensor that monitors the presence of draft in the flue of a gas water heater. This function is especially important for models with open combustion chambers: in the absence of a draft, combustion products will fill the room where the heater is located. And this, in turn, can lead to a deterioration in people's well-being, health problems and even deaths. To avoid such consequences, this sensor, when detecting problems with the draft, turns off the gas supply and issues a warning about the problem. However, such equipment can also be found in models with closed combustion chambers. In them, the draft sensor performs mainly a diagnostic function, allowing you to determine what interferes with the normal operation of the burner.
— Anti-legionella. A function that prevents the growth of pathogenic bacteria in the tank and water heater circuits. Some types of such bacteria can live and multiply in fairly hot water — up to 60 °C. To avoid this, the anti-legionella system monitors the temperature of the water in the tank and periodically raises it to a level of about 65 °C. The specific methods of operation of such systems can be different: for example, some work strictly according to a set schedule (for example, once every two weeks), others turn on additional heating only if for some period (for example, a month) the water has not been heated to sufficiently high temperatures.Pipe connection
The direction from which pipes are connected to the heater. The choice for this parameter depends primarily on the characteristics of the place where the device is planned to be placed. Note that in universal models (see "Installation"), the place of connection of pipes depends on the method of installation, while specific options in different models may be different, this should be specified separately.
Weight
The weight of the device, excluding the water collected (passing) into it.