Comparison Marsriva KP1 EC 18 VA vs YEPO UA-102822 36 VA

Add to comparison
Marsriva KP1 EC 18 VA
YEPO UA-102822 36 VA
Marsriva KP1 EC 18 VAYEPO UA-102822 36 VA
Outdated ProductOutdated Product
User reviews
0
0
0
2
12
0
0
TOP sellers
Output connectors 2 x DC 12 V 2.5 A, 1 x DC 9 V 2.5 A, 1 x DC 5 V 2.1 A.
Output connectors 1 x DC 5V 2A, 1 x DC 9V 2A, 1 x DC 12V 2A, 15/24V POE.
Typelow voltage UPS (router, camera)low voltage UPS (router, camera)
Form factorstandard (flat)standard (flat)
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range100 – 240 В85 – 265 В
Bypass (direct connection)is absentis absent
Output
Output voltageDC (constant voltage)DC (constant voltage)
Peak output power18 VA36 VA
Rated output power18 W
Charging USB A ports11
PoE output (LAN)15 H/24 H
Battery
Total battery capacity8 Ah10.4 Ah
Battery typeLi-ion (lithium-ion)Li-ion (lithium-ion)
Cold start
Protection
Protection
short circuit protection
overload protection
short circuit protection
overload protection
General
Operating temperature0 – 40 °C
Dimensions (HxWxD)32x108x173 mm32x160x102 mm
Weight0.34 kg0.42 kg
Added to E-Catalogoctober 2023october 2023
Glossary

Input voltage range

In this case, the input voltage range is implied, in which the UPS is able to supply a stable voltage to the load only due to its own regulators, without switching to the battery. For redundant UPSs (see "Type") this range is quite small, approximately 190 to 260 V; for interactive and especially inverter ones, it is much wider. Some UPS models allow you to manually set the input voltage range.

Peak output power

The maximum output power supplied by the UPS, in other words, the highest apparent load power allowed for this model.

This indicator is measured in volt-amperes (the general meaning of this unit is the same as that of the watt, and different names are used to separate different types of power). The total power consumption of the load, implied in this case, is the sum of two powers — active and reactive. Active power is actually effective power (it is indicated in watts in the characteristics of electrical appliances). Reactive power is the power wasted by coils and capacitors in AC devices; with numerous coils and/or capacitors, this power can be a fairly significant part of the total energy consumption. Note that for simple tasks, you can use data on effective power (it is often given for UPS — see below); but for accurate electrical calculations it is worth using the full one.

The simplest selection rule for this indicator is: the maximum output power of the UPS in volt-amperes should be at least 1.7 times higher than the total load power in watts. There are also more detailed calculation formulas that take into account the characteristics of different types of load; they can be found in special sources. As for specific values, the most modest modern UPSs give out 700 – 1000 VA, or even less — this is enough to power a PC of average performance; and in the most "heavyweight" models, th...is figure can be 8 – 10 kVA and higher.

Rated output power

The effective output power of the UPS is, in fact, the maximum active power of the load that can be connected to the device.

Active power is consumed directly for the operation of the device; it is expressed in watts. In addition to it, most AC devices also consume reactive power, which is "wasted" (relatively speaking) is spent by coils and capacitors. Apparent power (denoted in volt-amperes) is precisely the sum of active and reactive power; it is this characteristic that should be used in accurate electrical calculations. See "Maximum output power" for details; here we note that when selecting a UPS for a relatively simple application, it is quite possible to use only effective power. This is at least easier than converting the watts claimed in the characteristics of the connected devices into full power volt-amps.

The most modest modern "uninterruptibles" give out less than 500 watts. 501 – 1000 W can be considered an average value, 1.1 – 2 kW is above average, and in the most powerful models this figure exceeds 2 kW and can reach very impressive values (up to 1000 kW or more in some industrial class UPS).

PoE output (LAN)

Availability of a LAN connector in the UPS with support for PoE (Power over Ethernet) power supply. This technology allows energy to be transmitted via an Ethernet cable to power network devices. It is possible to power such devices directly from the UPS, which ensures equipment backup in case of power supply interruptions. Such devices include IP video surveillance cameras, access points, various sensors, etc.

Total battery capacity

The capacity of the battery installed in the UPS. For models with multiple batteries, this is both the total working capacity and the capacity of each individual battery: the batteries in such devices are usually connected in series, so that their total capacity corresponds to the capacity of each individual cell.

Theoretically, a higher battery capacity means the ability to power loads of a given capacity for longer. However, in fact, this parameter is more of a reference than practically significant. The fact is that the actual amount of energy stored by the battery depends not only on the capacity in amp-hours, but also on the voltage in volts; this voltage is often not specified in the characteristics, despite the fact that for accurate calculations it must be known. So when choosing, you should focus on more "close to life" characteristics — first of all, on the directly claimed operating time in different modes (see above).

Cold start

The ability to turn on the uninterruptible power supply in the "cold start" mode.

A cold start is a turn-on mode in which there is no external power, and the load connected to the UPS is powered immediately from the uninterruptible battery (which, of course, must be charged). This mode is especially useful in emergency cases — for example, if you urgently need to print a document, but there is no light.

Operating temperature

Ambient temperature range in which the UPS is guaranteed to maintain normal operation.

All modern "uninterruptible" without problems endure the temperatures typical for residential and office premises. Therefore, it makes sense to pay attention to this parameter if the device is planned to be used in more extreme conditions — for example, in an unheated room, or vice versa, in a production workshop with a high air temperature. At the same time, it's ok to take a margin for temperature: this will give a guarantee in case of unforeseen situations, besides, the wider the temperature range, the higher the overall resistance to adverse conditions.